{"id":56,"date":"2017-11-15T19:52:15","date_gmt":"2017-11-16T03:52:15","guid":{"rendered":"http:\/\/labs.wsu.edu\/thiessen\/?page_id=56"},"modified":"2019-11-11T11:31:56","modified_gmt":"2019-11-11T19:31:56","slug":"desktop-learning-modules","status":"publish","type":"page","link":"https:\/\/labs.wsu.edu\/educ-ate\/desktop-learning-modules\/","title":{"rendered":"Low-Cost Desktop Learning Modules"},"content":{"rendered":"<br \/>\n<section id=\"builder-section-1550296738943\" class=\"row single gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<p>We have developed low-cost, miniaturized, lightweight, see-through, easy\u00a0and safe to use desktop experiments\u00a0with which engineering students can conduct investigations to learn fundamental principles of fluid mechanics and heat transfer. The ultra-low-cost of the experiments make it possible for engaging investigations to be integrated widely throughout fluid mechanics and heat transfer courses. With a target cost comparable to a textbook, these experiments make it possible for teams of students to pursue their own investigations of fluids and heat transfer phenomena.<\/p>\n<\/p><\/div>\n<\/section>\n<section id=\"builder-section-1550297825509\" class=\"row single h1-header gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<h1>Fluid Mechanics LC-DLMs<\/h1>\n<\/p><\/div>\n<\/section>\n<section id=\"builder-section-1550297759631\" class=\"row halves gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<p style=\"text-align: center\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-899 aligncenter\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/2379\/2019\/02\/hydraulic_loss_injection_molded_cartridge-396x263.jpg\" alt=\"\" width=\"396\" height=\"263\" srcset=\"https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/02\/hydraulic_loss_injection_molded_cartridge-396x263.jpg 396w, https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/02\/hydraulic_loss_injection_molded_cartridge-768x510.jpg 768w, https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/02\/hydraulic_loss_injection_molded_cartridge-792x526.jpg 792w, https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/02\/hydraulic_loss_injection_molded_cartridge-990x658.jpg 990w, https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/02\/hydraulic_loss_injection_molded_cartridge-1188x789.jpg 1188w\" sizes=\"(max-width: 396px) 100vw, 396px\" \/>Hydraulic-loss cartridge<\/p>\n<\/p><\/div>\n<div style=\"\" class=\"column two \">\n<img class=\"size-medium aligncenter\" src=\"https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/11\/venturi_inj_molded_closeup-396x263.jpg\" width=\"396\" height=\"263\" \/>\n<p style=\"text-align: center\">Venturi meter cartridge<\/p>\n<\/p><\/div>\n<\/section>\n<section id=\"builder-section-1550297885133\" class=\"row single h1-header gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<h1>Heat Transfer LC-DLMs<\/h1>\n<\/p><\/div>\n<\/section>\n<section id=\"builder-section-1550298477715\" class=\"row halves gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-1055 aligncenter\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/2379\/2019\/04\/DSC_1078-396x263.jpg\" alt=\"\" width=\"396\" height=\"263\" srcset=\"https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/04\/DSC_1078-396x263.jpg 396w, https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/04\/DSC_1078-768x510.jpg 768w, https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/04\/DSC_1078-792x526.jpg 792w, https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/04\/DSC_1078-990x658.jpg 990w, https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/04\/DSC_1078-1188x789.jpg 1188w\" sizes=\"(max-width: 396px) 100vw, 396px\" \/><\/p>\n<p style=\"text-align: center\">Double-pipe heat exchanger cartridge<\/p>\n<\/p><\/div>\n<div style=\"\" class=\"column two \">\n<p style=\"text-align: center\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter wp-image-957 size-medium\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/2379\/2019\/03\/DSC_0353-396x263.jpg\" alt=\"\" width=\"396\" height=\"263\" srcset=\"https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/03\/DSC_0353-396x263.jpg 396w, https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/03\/DSC_0353-768x510.jpg 768w, https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/03\/DSC_0353-792x526.jpg 792w, https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/03\/DSC_0353-990x658.jpg 990w, https:\/\/wpcdn.web.wsu.edu\/wp-labs\/uploads\/sites\/2379\/2019\/03\/DSC_0353-1188x789.jpg 1188w\" sizes=\"(max-width: 396px) 100vw, 396px\" \/><\/p>\n<p style=\"text-align: center\">Shell-and-tube heat exchanger cartridge<\/p>\n<div class=\"mceTemp\"><\/div>\n<\/p><\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>We have developed low-cost, miniaturized, lightweight, see-through, easy\u00a0and safe to use desktop experiments\u00a0with which engineering students can conduct investigations to learn fundamental principles of fluid mechanics and heat transfer. The ultra-low-cost of the experiments make it possible for engaging investigations to be integrated widely throughout fluid mechanics and heat transfer courses. With a target cost [&hellip;]<\/p>\n","protected":false},"author":3439,"featured_media":0,"parent":0,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"template-builder.php","meta":[],"wsuwp_university_location":[],"wsuwp_university_org":[],"_links":{"self":[{"href":"https:\/\/labs.wsu.edu\/educ-ate\/wp-json\/wp\/v2\/pages\/56"}],"collection":[{"href":"https:\/\/labs.wsu.edu\/educ-ate\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/labs.wsu.edu\/educ-ate\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/labs.wsu.edu\/educ-ate\/wp-json\/wp\/v2\/users\/3439"}],"replies":[{"embeddable":true,"href":"https:\/\/labs.wsu.edu\/educ-ate\/wp-json\/wp\/v2\/comments?post=56"}],"version-history":[{"count":42,"href":"https:\/\/labs.wsu.edu\/educ-ate\/wp-json\/wp\/v2\/pages\/56\/revisions"}],"predecessor-version":[{"id":1428,"href":"https:\/\/labs.wsu.edu\/educ-ate\/wp-json\/wp\/v2\/pages\/56\/revisions\/1428"}],"wp:attachment":[{"href":"https:\/\/labs.wsu.edu\/educ-ate\/wp-json\/wp\/v2\/media?parent=56"}],"wp:term":[{"taxonomy":"wsuwp_university_location","embeddable":true,"href":"https:\/\/labs.wsu.edu\/educ-ate\/wp-json\/wp\/v2\/wsuwp_university_location?post=56"},{"taxonomy":"wsuwp_university_org","embeddable":true,"href":"https:\/\/labs.wsu.edu\/educ-ate\/wp-json\/wp\/v2\/wsuwp_university_org?post=56"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}